Project Information | |||
---|---|---|---|
Project Name: | Demo Building | ||
Project Location: | Seattle, WA | ||
Default Heating Temperature: | 75° F | Heating Safety Factor (Room): | 0% |
Heating Safety Factor (Ventilation): | 0% | ||
Default Cooling Temperature: | 75° F | Cooling Safety Factor (Room): | 0% |
Cooling Safety Factor (Ventilation): | 0% | ||
Default Relative Humidity: | 50% | Floor Slab Heat Loss Coefficient: | 0.54 |
Calculation Date: | July 25, 2006, 4:27 p.m. | ||
Design Conditions | |||
OSA Low: | 28° F |
Latitude: | 48° N |
OSA Daily Range: | 18° F |
Elevation: | 446' |
OSA High Dry Bulb | OSA High Wet Bulb | ||
June | 84° F |
64° F |
|
July | 87° F |
66° F |
|
August | 87° F |
66° F |
Roof Types | ||||
---|---|---|---|---|
Roof Type | U-Value | ASHRAE Type | Color | Description |
R19 in Attic | 0.0526 |
2 |
Dark | Insulation on attic floor, R19 |
R19 on Steel | 0.0526 |
2 |
Dark | Insulation on steel, R19 |
Roofs | |||
---|---|---|---|
Location | Type | Area | |
Floor Ground (Excluding rooms listed below) | R19 in Attic | 2,100 ft2 |
|
Room 102 | R19 on Steel | (100% of Room) |
921 ft2 |
Room 103 | R19 in Attic | (50% of Room) |
136 ft2 |
Room 105 | R19 in Attic | (100% of Room) |
271 ft2 |
Room 107 | R19 in Attic | (100% of Room) |
253 ft2 |
Wall Types | ||||
---|---|---|---|---|
Wall Type | U-Value | ASHRAE Type | Color | Description |
BRK - GWB - R19 | 0.053 |
14 |
Dark | Brick - GWB - R19 |
Walls | ||||||
---|---|---|---|---|---|---|
Room Number | Length | Height | Area (Minus Doors and Glass) | Type | Facing Direction | On Perimeter |
101 | 9'-8" |
10'-0" |
73 ft2 |
BRK - GWB - R19 | N | |
101 | 9'-8" |
10'-0" |
73 ft2 |
BRK - GWB - R19 | W | |
101 | 41'-6" |
10'-0" |
263 ft2 |
BRK - GWB - R19 | S | |
101 | 25'-8" |
10'-0" |
192 ft2 |
BRK - GWB - R19 | E | |
102 | 37'-2" |
10'-0" |
279 ft2 |
BRK - GWB - R19 | E | |
103 | 15'-5" |
10'-0" |
116 ft2 |
BRK - GWB - R19 | W | |
103 | 17'-7" |
10'-0" |
132 ft2 |
BRK - GWB - R19 | S | |
104 | 18'-9" |
10'-0" |
187 ft2 |
BRK - GWB - R19 | W | |
104 | 36'-1" |
10'-0" |
361 ft2 |
BRK - GWB - R19 | N | |
105 | 15'-5" |
10'-0" |
116 ft2 |
BRK - GWB - R19 | W | |
105 | 5'-2" |
10'-0" |
39 ft2 |
BRK - GWB - R19 | N | |
106 | 7'-1" |
10'-0" |
53 ft2 |
BRK - GWB - R19 | N | |
106 | 18'-9" |
10'-0" |
140 ft2 |
BRK - GWB - R19 | E | |
107 | 21'-2" |
10'-0" |
159 ft2 |
BRK - GWB - R19 | W |
Door Types | ||||
---|---|---|---|---|
Door Type | U-Value | ASHRAE Type | Color | Description |
Steel, Ins | 0.3 |
2 |
Dark | Steel, insulated |
Doors | |||
---|---|---|---|
Room Number | Area | Type | Facing Direction |
101 | 48 ft2 |
Steel, Ins | S |
Glass Types | ||||
---|---|---|---|---|
Glass Type | U-Value | SHGC | Description | |
Al, DG, 1/2", LE, F | 0.47 |
1 |
Aluminum Double glazing, 1/2" air space, w/o thermal break, low E = .1, fixed |
Glass | ||||
---|---|---|---|---|
Room Number | Area | Type | Facing Direction | Shaded |
101 | 24 ft2 |
Al, DG, 1/2", LE, F | N | |
101 | 24 ft2 |
Al, DG, 1/2", LE, F | W | |
101 | 104 ft2 |
Al, DG, 1/2", LE, F | S | |
101 | 64 ft2 |
Al, DG, 1/2", LE, F | E | |
102 | 93 ft2 |
Al, DG, 1/2", LE, F | E | |
103 | 39 ft2 |
Al, DG, 1/2", LE, F | W | |
103 | 44 ft2 |
Al, DG, 1/2", LE, F | S | |
105 | 39 ft2 |
Al, DG, 1/2", LE, F | W | |
105 | 13 ft2 |
Al, DG, 1/2", LE, F | N | |
106 | 18 ft2 |
Al, DG, 1/2", LE, F | N | |
106 | 47 ft2 |
Al, DG, 1/2", LE, F | E | |
107 | 53 ft2 |
Al, DG, 1/2", LE, F | W |
Room Information, Part 1 | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Values in italics have been changed from the default | ||||||||||||||
Number | Name | Area | Ceiling Height |
Ventilation | Infiltration | Cooling Temperature |
Heating Temperature |
Relative Humidity |
||||||
Cooling | Heating | Cooling | Heating | |||||||||||
101 | Auditorium | 1,290 ft2 |
8'-0" |
15 CFM / person |
193 CFM |
Same as cooling | 0.25 AC / hour |
43 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
102 | Meeting | 921 ft2 |
8'-0" |
0.5 CFM / ft2 |
461 CFM |
Same as cooling | 0 AC / hour |
0 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
103 | Office | 271 ft2 |
8'-0" |
15 CFM / person |
41 CFM |
Same as cooling | 0.25 AC / hour |
9 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
104 | Office | 676 ft2 |
8'-0" |
15 CFM / person |
101 CFM |
Same as cooling | 0.25 AC / hour |
23 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
105 | Office | 271 ft2 |
8'-0" |
15 CFM / person |
41 CFM |
Same as cooling | 0.25 AC / hour |
9 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
106 | Storage | 133 ft2 |
8'-0" |
1 CFM / ft2 |
133 CFM |
Same as cooling | 0.25 AC / hour |
4 CFM |
Same as cooling | 75° F |
75° F |
50% |
||
107 | Office | 253 ft2 |
8'-0" |
15 CFM / person |
38 CFM |
Same as cooling | 0.25 AC / hour |
8 CFM |
Same as cooling | 75° F |
75° F |
50% |
Room Information, Part 2 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Values in italics have been changed from the default | ||||||||||
Number | Lighting Load | Equipment Load | People | Glass Zone Type |
||||||
Sensible | Latent | Sensible btuh / Person | Latent btuh / Person | |||||||
101 | 2 watts / ft2 |
8,800 |
0.5 watts / ft2 |
2,200 |
0 |
6.6 ft2 / person |
12.9 people |
230 |
230 |
B |
102 | 2.2 watts / ft2 |
6,920 |
0 |
0 |
20 ft2 / person |
92.1 people |
230 |
230 |
B | |
103 | 1 watts / ft2 |
926 |
0.5 watts / ft2 |
463 |
0 |
100 ft2 / person |
2.7 people |
230 |
230 |
B |
104 | 1.3 watts / ft2 |
3,000 |
2 watts / ft2 |
4,620 |
0 |
100 ft2 / person |
6.8 people |
250 |
200 |
C |
105 | 1 watts / ft2 |
926 |
0.5 watts / ft2 |
463 |
0 |
100 ft2 / person |
2.7 people |
230 |
230 |
B |
106 | 0.6 watts / ft2 |
273 |
0 |
0 |
200 ft2 / person |
0.7 people |
250 |
200 |
C | |
107 | 1 watts / ft2 |
862 |
0.5 watts / ft2 |
431 |
0 |
100 ft2 / person |
2.5 people |
230 |
230 |
B |
Supply Air Requirements | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Current Supply CFM |
Required Supply CFM |
Cooling | Heating | ||||||||||
Peak | Supply Temperature |
Load (btuh) | Supply CFM |
OSA CFM |
OSA % |
Heating Temperature Difference |
Load (btuh) | Supply CFM |
OSA CFM |
OSA % |
||||
Zone BLDG | 600 |
0 |
June | 4:00 a.m. | 55° F |
0 |
0 |
0 |
0% |
20° F dT |
0 |
0 |
0 |
0% |
Room 101 | 0 |
2,090 |
August | 2:00 p.m. | 48,000 |
2,090 |
193 |
9% |
14,500 |
681 |
193 |
28% |
||
Room 102 | 0 |
2,140 |
July | 9:00 a.m. | 67,500 |
2,140 |
461 |
22% |
5,960 |
461 |
461 |
100% |
||
Room 104 | 0 |
585 |
July | 3:00 p.m. | 14,000 |
585 |
101 |
17% |
5,550 |
261 |
101 |
39% |
||
Room 106 | 0 |
419 |
June | 8:00 a.m. | 9,180 |
419 |
133 |
32% |
3,120 |
147 |
133 |
90% |
||
Zone Main | 600 |
0 |
June | 4:00 a.m. | 55° F |
0 |
0 |
0 |
0% |
20° F dT |
0 |
0 |
0 |
0% |
Room 103 | 300 |
701 |
August | 3:00 p.m. | 15,800 |
701 |
41 |
6% |
4,070 |
191 |
41 |
21% |
||
Room 105 | 300 |
537 |
July | 5:00 p.m. | 12,200 |
537 |
41 |
8% |
3,170 |
149 |
41 |
28% |
||
Room 107 | 0 |
642 |
July | 5:00 p.m. | 14,500 |
642 |
38 |
6% |
3,150 |
148 |
38 |
26% |
Heating Load Detail - System and Room (btuh / % of System Total) | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Ventilation | Plenum | Roof | Wall | Glass | Slab | Vertical Partitions |
Horizontal Partitions |
Infiltration | |||||||||
Zone BLDG | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Room 101 | 9,660 |
40% |
0 |
0% |
3,190 |
13% |
2,170 |
9% |
4,780 |
20% |
2,200 |
9% |
0 |
0% |
0 |
0% |
2,150 |
9% |
Room 102 | 23,000 |
79% |
0 |
0% |
2,280 |
8% |
694 |
2% |
2,050 |
7% |
943 |
3% |
0 |
0% |
0 |
0% |
0 |
0% |
Room 104 | 5,070 |
48% |
0 |
0% |
1,670 |
16% |
1,370 |
13% |
0 |
0% |
1,390 |
13% |
0 |
0% |
0 |
0% |
1,130 |
11% |
Room 106 | 6,660 |
68% |
0 |
0% |
330 |
3% |
483 |
5% |
1,430 |
15% |
656 |
7% |
0 |
0% |
0 |
0% |
222 |
2% |
Zone Main | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Room 103 | 2,030 |
33% |
0 |
0% |
335 |
6% |
617 |
10% |
1,820 |
30% |
838 |
14% |
0 |
0% |
0 |
0% |
452 |
7% |
Room 105 | 2,030 |
39% |
0 |
0% |
671 |
13% |
385 |
7% |
1,140 |
22% |
523 |
10% |
0 |
0% |
0 |
0% |
452 |
9% |
Room 107 | 1,890 |
38% |
0 |
0% |
624 |
12% |
396 |
8% |
1,170 |
23% |
538 |
11% |
0 |
0% |
0 |
0% |
420 |
8% |
Cooling Load Details - System (btuh / % Total) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(See Cooling Load Detail - Room for lighting, equipment, and people loads) | ||||||||||||||||||||||
Location | Peak | Ventilation | Plenum | Roof | Wall | Glass | Horizontal Partitions |
Vertical Partitions |
Infiltration | |||||||||||||
Sensible | Latent | Sensible | Latent | |||||||||||||||||||
Zone BLDG | June | 4:00 a.m. | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Zone Main | June | 4:00 a.m. | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Cooling Load Details - Room (btuh / % of Total) | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Peak | Roof | Wall | Glass | Horizontal Partitions |
Vertical Partitions |
Lighting | Equipment | People | Infiltration | ||||||||||||||||
Sensible | Latent | Sensible | Latent | Sensible | Latent | |||||||||||||||||||||
Zone BLDG | June | 4:00 a.m. | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Room 101 | August | 2:00 p.m. | 4,550 |
9% |
1,290 |
3% |
24,800 |
52% |
0 |
0% |
0 |
0% |
8,800 |
18% |
2,200 |
5% |
0 |
0% |
2,970 |
6% |
2,970 |
6% |
524 |
1% |
-62 |
0% |
Room 102 | July | 9:00 a.m. | 727 |
1% |
207 |
0% |
17,300 |
26% |
0 |
0% |
0 |
0% |
6,920 |
10% |
0 |
0% |
0 |
0% |
21,200 |
31% |
21,200 |
31% |
0 |
0% |
0 |
0% |
Room 104 | July | 3:00 p.m. | 2,770 |
20% |
292 |
2% |
0 |
0% |
0 |
0% |
0 |
0% |
3,000 |
21% |
4,620 |
33% |
0 |
0% |
1,690 |
12% |
1,350 |
10% |
287 |
2% |
-32 |
0% |
Room 106 | June | 8:00 a.m. | 14 |
0% |
86 |
1% |
8,550 |
93% |
0 |
0% |
0 |
0% |
273 |
3% |
0 |
0% |
0 |
0% |
167 |
2% |
133 |
1% |
-29 |
0% |
-22 |
0% |
Zone Main | June | 4:00 a.m. | 0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
0 |
0% |
Room 103 | August | 3:00 p.m. | 507 |
3% |
213 |
1% |
12,300 |
78% |
0 |
0% |
0 |
0% |
926 |
6% |
463 |
3% |
0 |
0% |
624 |
4% |
624 |
4% |
115 |
1% |
-13 |
0% |
Room 105 | July | 5:00 p.m. | 1,030 |
8% |
131 |
1% |
8,360 |
68% |
0 |
0% |
0 |
0% |
926 |
8% |
463 |
4% |
0 |
0% |
624 |
5% |
624 |
5% |
98 |
1% |
-13 |
0% |
Room 107 | July | 5:00 p.m. | 956 |
7% |
152 |
1% |
10,800 |
75% |
0 |
0% |
0 |
0% |
862 |
6% |
431 |
3% |
0 |
0% |
581 |
4% |
581 |
4% |
91 |
1% |
-12 |
0% |
Load Total Summary - System (Includes Ventilation and Plenum Loads) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Area | Heating | Cooling | ||||||||||||||
CFM | btuh | kW | CFM / ft2 | CFM | Peak | btuh | Tons | ft2 / ton | CFM / ton | CFM / ft2 | |||||||
Total | Sensible | Latent | Total | Sensible | Latent | ||||||||||||
Zone BLDG | 0 ft2 |
0 |
0 |
0 |
0 |
June | 4:00 a.m. | 0 |
0 |
0 |
0 |
0 |
0 |
||||
Zone Main | 0 ft2 |
0 |
0 |
0 |
0 |
June | 4:00 a.m. | 0 |
0 |
0 |
0 |
0 |
0 |
Load Total Summary - Room (Excludes Ventilation and Plenum Loads) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Area | Heating | Cooling | ||||||||||||||
CFM | btuh | kW | CFM / ft2 | CFM | Peak | btuh | Tons | ft2 / ton | CFM / ton | CFM / ft2 | |||||||
Total | Sensible | Latent | Total | Sensible | Latent | ||||||||||||
Zone BLDG | 0 ft2 |
0 |
0 |
0 |
0 |
June | 4:00 a.m. | 0 |
0 |
0 |
0 |
0 |
0 |
||||
Room 101 | 1,290 ft2 |
681 |
14,500 |
4.2 |
0.53 |
2,090 |
August | 2:00 p.m. | 48,000 |
45,100 |
2,910 |
4 |
3.8 |
0.2 |
322 |
521 |
1.62 |
Room 102 | 921 ft2 |
461 |
5,960 |
1.7 |
0.5 |
2,140 |
July | 9:00 a.m. | 67,500 |
46,300 |
21,200 |
5.6 |
3.9 |
1.8 |
164 |
380 |
2.32 |
Room 104 | 676 ft2 |
261 |
5,550 |
1.6 |
0.39 |
585 |
July | 3:00 p.m. | 14,000 |
12,700 |
1,320 |
1.2 |
1.1 |
0.1 |
580 |
502 |
0.87 |
Room 106 | 133 ft2 |
147 |
3,120 |
0.9 |
1.1 |
419 |
June | 8:00 a.m. | 9,180 |
9,060 |
112 |
0.8 |
0.8 |
0 |
174 |
548 |
3.14 |
Zone Main | 0 ft2 |
0 |
0 |
0 |
0 |
June | 4:00 a.m. | 0 |
0 |
0 |
0 |
0 |
0 |
||||
Room 103 | 271 ft2 |
191 |
4,070 |
1.2 |
0.7 |
701 |
August | 3:00 p.m. | 15,800 |
15,200 |
611 |
1.3 |
1.3 |
0.1 |
206 |
533 |
2.58 |
Room 105 | 271 ft2 |
149 |
3,170 |
0.9 |
0.55 |
537 |
July | 5:00 p.m. | 12,200 |
11,600 |
611 |
1 |
1 |
0.1 |
266 |
526 |
1.98 |
Room 107 | 253 ft2 |
148 |
3,150 |
0.9 |
0.59 |
642 |
July | 5:00 p.m. | 14,500 |
13,900 |
569 |
1.2 |
1.2 |
0 |
210 |
533 |
2.54 |
Psychrometrics - Zone BLDG | |||||||
---|---|---|---|---|---|---|---|
Peak Month: | June | Peak Time: | 4:00 a.m. | ||||
Airflow (CFM) |
Air Conditions | Loads (btuh) | |||||
Dry Bulb Temperature |
Wet Bulb Temperature |
Humidity Ratio (lbs of moisture / lb of dry air) |
Total | Sensible | Latent | ||
Outside Air | 0 |
66.18° F |
57.65° F |
0.00841 |
0 |
0 |
0 |
Return Air at Diffusers | 0 |
0° F |
0° F |
0.00000 |
|||
Return Duct Leakage | (0%) 0 |
||||||
Return Duct Temperature Gain | +0° F |
0 |
0 |
0 |
|||
Return Air at Aparatus | 0 |
0° F |
0° F |
0.00000 |
|||
Mixed Air | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Entering Air | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Dew Point | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Bypass Air | (15%) 0 |
0° F |
0° F |
0.00000 |
|||
Coil Leaving Air | 0 |
0° F |
0° F |
0.00000 |
|||
System Load | 0 |
0 |
0 |
||||
Reheat | +55° F |
||||||
Fan (Draw Through, 2 HP) | +0° F |
0 |
0 |
0 |
|||
Motor (In Airstream, 70% Efficient) | +0° F |
0 |
0 |
0 |
|||
Supply Duct Leakage | (0%) 0 |
||||||
Supply Duct Temperature Gain | +0° F |
0 |
0 |
0 |
|||
Supply Air at Diffusers | 0 |
55° F |
35.23° F |
0.00000 |
|||
Room Load | 0.00000 |
0 |
0 |
0 |
|||
Final Room Conditions | 0° F |
0° F |
0.00000 |
Psychrometrics - Zone Main | |||||||
---|---|---|---|---|---|---|---|
Peak Month: | June | Peak Time: | 4:00 a.m. | ||||
Airflow (CFM) |
Air Conditions | Loads (btuh) | |||||
Dry Bulb Temperature |
Wet Bulb Temperature |
Humidity Ratio (lbs of moisture / lb of dry air) |
Total | Sensible | Latent | ||
Outside Air | 0 |
66.18° F |
57.65° F |
0.00841 |
0 |
0 |
0 |
Return Air at Diffusers | 0 |
0° F |
0° F |
0.00000 |
|||
Return Duct Leakage | (0%) 0 |
||||||
Return Duct Temperature Gain | +0° F |
0 |
0 |
0 |
|||
Return Air at Aparatus | 0 |
0° F |
0° F |
0.00000 |
|||
Mixed Air | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Entering Air | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Dew Point | 0 |
0° F |
0° F |
0.00000 |
|||
Coil Bypass Air | (15%) 0 |
0° F |
0° F |
0.00000 |
|||
Coil Leaving Air | 0 |
0° F |
0° F |
0.00000 |
|||
System Load | 0 |
0 |
0 |
||||
Reheat | +55° F |
||||||
Fan (Draw Through, 2 HP) | +0° F |
0 |
0 |
0 |
|||
Motor (In Airstream, 70% Efficient) | +0° F |
0 |
0 |
0 |
|||
Supply Duct Leakage | (0%) 0 |
||||||
Supply Duct Temperature Gain | +0° F |
0 |
0 |
0 |
|||
Supply Air at Diffusers | 0 |
55° F |
35.23° F |
0.00000 |
|||
Room Load | 0.00000 |
0 |
0 |
0 |
|||
Final Room Conditions | 0° F |
0° F |
0.00000 |