Edit UPS / Phase Inverter List
To edit UPS and phase inverter list project settings, go to
Ribbon:
Pulldown Menu:
To edit UPS and phase inverter list master settings, go to
Ribbon:
Pulldown Menu:
UPS List Label Display and Order Dialog Box
See the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.
Values in the Key ☰ column are listed alphabetically below.
-
AIC This value is taken from the UPS definition.
-
Bypass Feeder Size This value is taken from the UPS definition.
-
Bypass Upstream OCP This value is taken from the UPS definition.
-
Bypass Upstream Breaker and Poles The size of the breaker and number of poles for the UPS bypass feeder.
Examples: 20/1, 30/3
-
Bypass Upstream Circuit The circuit to which the UPS is connected on the upstream device for bypass power.
-
Bypass Upstream Device The upstream device to which the UPS is connected for bypass power.
-
Callout The name of the UPS.
-
Efficiency This value is taken from the UPS definition.
-
Fault The total fault in amps at the UPS, including the fault from the utility and the fault from any motors in the system.
-
IG Bus This value is taken from the UPS definition.
-
Input KVA This value is taken from the UPS definition.
-
Input Short Voltage The input voltage value and poles of the UPS.
Examples: 208Y/120V 1P, 208V 2P
-
Input Volts The full input voltage value of the UPS. The volts, poles, and wires will be displayed.
Examples: 208Y/120V 1P 2W, 208V 2P 2W
-
Input Volts Only The input voltage value of the UPS. Only the volts will be displayed. The poles and wires will not be displayed.
Examples: 208Y/120V, 208V
-
KVA This value is taken from the UPS definition.
-
KW This value is taken from the UPS definition.
-
List Note 1 This value is taken from the UPS definition.
-
List Note 2 This value is taken from the UPS definition.
-
List Note 3 This value is taken from the UPS definition.
-
Location This value is taken from the UPS definition.
-
Manufacturer This value is taken from the UPS definition.
-
Model This value is taken from the UPS definition.
-
Mounting This value is taken from the UPS definition.
-
NEMA This value is taken from the UPS definition.
-
Normal Feeder Size This value is taken from the UPS definition.
-
Normal Upstream Breaker and Poles The size of the breaker and number of poles for the UPS normal feeder.
Examples: 20/1, 30/3
-
Normal Upstream Circuit The circuit to which the UPS is connected on the upstream device for normal power.
-
Normal Upstream Device The upstream device to which the UPS is connected normal power.
-
Normal Upstream OCP This value is taken from the UPS definition.
-
Note 1 This value is taken from the UPS definition.
-
Note 2 This value is taken from the UPS definition.
-
Output Short Voltage The output voltage value and poles of the UPS.
Examples: 208Y/120V 1P, 208V 2P
-
Output Volts The full output voltage value of the UPS. The volts, poles, and wires will be displayed.
Examples: 208Y/120V 1P 2W, 208V 2P 2W
-
Output Volts Only The output voltage value of the UPS. Only the volts will be displayed. The poles and wires will not be displayed.
Examples: 208Y/120V, 208V
-
Power Factor This value is taken from the UPS definition.
-
Taps This value is taken from the UPS definition.
-
Total Calculated Amps The total calculated load in amps of the UPS.
-
Total Calculated KVA The total calculated load in kVA of the UPS.
-
Total Connected Amps The total calculated load in amps of the UPS.
-
Total Connected KVA The total calculated load in kVA of the UPS.
-
Utility Fault The utility fault in amps at the UPS.
tipUse this column instead of the Fault column if you do not want to include motor contributions.