Edit Recurring Panel Instance List

To edit recurring panel instance list project settings, go to
Ribbon: DME: Customization→Project Customization→  Recurring Panel Instance List Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Project List→Edit Recurring Panel Instance List

To edit recurring panel instance list master settings, go to
Ribbon: DME: Customization→Master & Standards Customization→  Edit Distribution Equipment Master Groups
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Standards and Master Lists→Edit Distribution Equipment Master Groups

Recurring Panel Instance List Label Display and Order Dialog Box

See the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.

Values in the Key ☰ column are listed alphabetically below.

  •  AIC This value is taken from the recurring panel instance definition.

  •  Bus Amps This value is taken from the recurring panel instance definition.

  •  Callout The name of the recurring panel instance.

  •  Fault The total fault in amps at the recurring panel instance, including the fault from the utility and the fault from any motors in the system.

  •  Feeder Size This value is taken from the recurring panel instance definition.

  •  IG Bus This value is taken from the recurring panel instance definition.

  •  List Note 1 This value is taken from the recurring panel instance definition.

  •  List Note 2 This value is taken from the recurring panel instance definition.

  •  List Note 3 This value is taken from the recurring panel instance definition.

  •  Location This value is taken from the recurring panel instance definition.

  •  Lugs This value is taken from the recurring panel instance definition.

  •  Main Disconnect Amps This value is taken from the recurring panel instance definition.

  •  Main Disconnect Type This value is taken from the recurring panel instance definition.

  •  Manufacturer This value is taken from the recurring panel instance definition.

  •  Model This value is taken from the recurring panel instance definition.

  •  Mounting This value is taken from the recurring panel instance definition.

  •  NEMA This value is taken from the recurring panel instance definition.

  •  Note 1 This value is taken from the recurring panel instance definition.

  •  Note 2 This value is taken from the recurring panel instance definition.

  •  Panel Neutral This value is taken from the recurring panel instance definition.

  •  Poles This value is taken from the recurring panel instance definition.

  •  Recurring Panel Instance The template the recurring panel instance is based upon.

  •  Short Voltage The voltage value and poles of the recurring panel instance.

    Examples: 120V 1P, 208V 2P

  •  Total Calculated Amps The total calculated load in amps of the recurring panel instance.

  •  Total Calculated KVA The total calculated load in kVA of the recurring panel instance.

  •  Total Connected Amps The total calculated load in amps of the recurring panel instance.

  •  Total Connected KVA The total calculated load in kVA of the recurring panel instance.

  •  Upstream Breaker and Poles The size of the breaker and number of poles for the recurring panel instance feeder.

    Examples: 20/1, 30/3

  •  Upstream Circuit The circuit to which the recurring panel instance is connected on the upstream device.

  •  Upstream Device The upstream device to which the recurring panel instance is connected.

  •  Upstream OCP This value is taken from the recurring panel instance definition.

  •  Utility Fault The utility fault in amps at the recurring panel instance.

    tip

    Use this column instead of the Fault column if you do not want to include motor contributions.

  •  Volts The full voltage value of the recurring panel instance. The volts, poles, and wires will be displayed.

    Examples: 120V 1P 2W, 208V 2P 2W

  •  Volts Only The voltage value of the recurring panel instance. Only the volts will be displayed. The poles and wires will not be displayed.

    Examples: 120V, 208V