Edit Enclosed Breaker / Disconnect List

To edit enclosed breaker and disconnect list project settings, go to
Ribbon: DME: Customization→Project Customization→  Enclosed Breaker / Disconnect List Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Project List→Edit Enclosed Breaker / Disconnect List

To edit enclosed breaker and disconnect list master settings, go to
Ribbon: DME: Customization→Master & Standards Customization→  Edit Distribution Equipment Master Groups
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Standards and Master Lists→Edit Distribution Equipment Master Groups

Enclosed Breaker List Label Display and Order Dialog Box

See the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.

Values in the Key ☰ column are listed alphabetically below.

  •  AIC This value is taken from the enclosed breaker definition.

  •  Breaker Bus Amps This value is taken from the enclosed breaker definition.

  •  Callout The name of the enclosed breaker.

  •  Fault The total fault in amps at the enclosed breaker, including the fault from the utility and the fault from any motors in the system.

  •  Feeder Size This value is taken from the enclosed breaker definition.

  •  Frame Size This value is taken from the enclosed breaker definition.

  •  List Note 1 This value is taken from the enclosed breaker definition.

  •  List Note 2 This value is taken from the enclosed breaker definition.

  •  List Note 3 This value is taken from the enclosed breaker definition.

  •  Location This value is taken from the enclosed breaker definition.

  •  Lugs This value is taken from the enclosed breaker definition.

  •  Manufacturer This value is taken from the enclosed breaker definition.

  •  Model This value is taken from the enclosed breaker definition.

  •  Mounting This value is taken from the enclosed breaker definition.

  •  NEMA This value is taken from the enclosed breaker definition.

  •  Note 1 This value is taken from the enclosed breaker definition.

  •  Note 2 This value is taken from the enclosed breaker definition.

  •  Number of Taps This value is taken from the enclosed breaker definition.

  •  Short Voltage The voltage value and poles of the enclosed breaker.

    Examples: 208Y/120V 1P, 208V 2P

  •  Total Calculated Amps The total calculated load in amps of the enclosed breaker.

  •  Total Calculated KVA The total calculated load in kVA of the enclosed breaker.

  •  Total Connected Amps The total calculated load in amps of the enclosed breaker.

  •  Total Connected KVA The total calculated load in kVA of the enclosed breaker.

  •  Type This value is taken from the enclosed breaker definition.

  •  Upstream Breaker and Poles The size of the breaker and number of poles for the enclosed breaker feeder.

    Examples: 20/1, 30/3

  •  Upstream Circuit The circuit to which the enclosed breaker is connected on the upstream device.

  •  Upstream Device The upstream device to which the enclosed breaker is connected.

  •  Upstream OCP This value is taken from the enclosed breaker definition.

  •  Utility Fault The utility fault in amps at the enclosed breaker.

    tip

    Use this column instead of the Fault column if you do not want to include motor contributions.

  •  Volts The full voltage value of the enclosed breaker. The volts, poles, and wires will be displayed.

    Examples: 208Y/120V 1P 2W, 208V 2P 2W

  •  Volts Only The voltage value of the enclosed breaker. Only the volts will be displayed. The poles and wires will not be displayed.

    Examples: 208Y/120V, 208V