Skip to main content

Edit Egress Photometric Area Schedule List

The Edit Egress Photometric Area Schedule List commands are used to modify the labels that appear on egress photometric calculation area schedules on the drawing.

warning

Each row that is displayed is included as a row in the schedule. They do not correspond to columns like in other schedules. To set the width of the columns, use the two special values, Label Column Width and Value Column Width.

To edit the egress photometric area schedule project settings, go to
Ribbon: DME: Customization→Project Customization→  Egress Photometric Area Schedule Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Project List→Edit Egress Photometric Area Schedule Project List

To edit the egress photometric area schedule standards settings, go to
Ribbon: DME: Customization→Master & Standards Customization→  Egress Photometric Area Schedule Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Standards and Master Lists→Edit Egress Photometric Area Schedule Standards List

Egress Photometric Schedule Label Display and Order Dialog Box

See the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.

Values in the Key ☰ column are listed alphabetically below.

  •  Average Illuminance The average illuminance value in the photometric calculation area.

  •  Average to Maximum Illuminance Ratio Equal to AverageIlluminanceMaximumIlluminanceAverage\>Illuminance \over Maximum\>Illuminance.

  •  Average to Maximum Vertical Illuminance Ratio Equal to AverageVerticalIlluminanceMaximumVerticalIlluminanceAverage\>Vertical\>Illuminance \over Maximum\>Vertical\>Illuminance.

  •  Average to Minimum Illuminance Ratio Equal to AverageIlluminanceMinimumIlluminanceAverage\>Illuminance \over Minimum\>Illuminance.

  •  Average to Minimum Vertical Illuminance Ratio Equal to AverageVerticalIlluminanceMinmumVerticalIlluminanceAverage\>Vertical\>Illuminance \over Minmum\>Vertical\>Illuminance.

  •  Average Vertical Illuminance The average vertical illuminance value in the photometric calculation area.

  •  Label Column Width The width of the label column in the schedule.

  •  Maximum Illuminance The maximum illuminance value in the photometric calculation area.

  •  Maximum to Average Illuminance Ratio Equal to MaximumIlluminanceAverageIlluminanceMaximum\>Illuminance \over Average\>Illuminance.

  •  Maximum to Average Vertical Illuminance Ratio Equal to MaximumVerticalIlluminanceAverageVerticalIlluminanceMaximum\>Vertical\>Illuminance \over Average\>Vertical\>Illuminance.

  •  Maximum to Minimum Illuminance Ratio Equal to MaximumIlluminanceMinimumIlluminanceMaximum\>Illuminance \over Minimum\>Illuminance.

  •  Maximum to Minimum Vertical Illuminance Ratio Equal to MaximumVerticalIlluminanceMinimumVerticalIlluminanceMaximum\>Vertical\>Illuminance \over Minimum\>Vertical\>Illuminance.

  •  Maximum Vertical Illuminance The maximum vertical illuminance value in the photometric calculation area.

  •  Minimum Illuminance The minimum illuminance value in the photometric calculation area.

  •  Minimum to Average Illuminance Ratio Equal to MinimumIlluminanceAverageIlluminanceMinimum\>Illuminance \over Average\>Illuminance.

  •  Minimum to Average Vertical Illuminance Ratio Equal to MinimumVerticalIlluminanceAverageVerticalIlluminanceMinimum\>Vertical\>Illuminance \over Average\>Vertical\>Illuminance.

  •  Minimum to Maximum Illuminance Ratio Equal to MinimumIlluminanceMaximumIlluminanceMinimum\>Illuminance \over Maximum\>Illuminance.

  •  Minimum to Maximum Vertical Illuminance Ratio Equal to MinimumVerticalIlluminanceMaximumVerticalIlluminanceMinimum\>Vertical\>Illuminance \over Maximum\>Vertical\>Illuminance.

  •  Minimum Vertical Illuminance The minimum vertical illuminance value in the photometric calculation area.

  •  Value Column Width The width of the value column in the schedule.