Using IES Files
This tutorial teaches you how to add IES files to your light fixtures in the schedule. An IES file is required to use a light fixture in photometric calculations. You need to obtain the IES file outside of Design Master Electrical. They are available on the manufacturer's websites.
Open drawing E-3.1.
Create Light Fixture Type S​
-
Run the
Light Fixture Project Schedule command. The Light Fixture Project Schedule dialog box will open.
Ribbon:DM Electrical→Devices→ Light Fixture Project Schedule
Pulldown Menu:DM Electrical→Light Fixtures→Light Fixture Project Schedule -
Press the button. The New dialog box will open.
-
Set New Light Fixture Callout to S.
-
Press the button to create the light fixture type.
-
Press the button. The Select Light Fixture Block dialog box will open.
-
Set Light Fixture Description ☰ to Single Pole Mounted. It will be near the bottom of the list.
-
Press the button to set the block.
-
In the IES File section, press the button. The Select IES File dialog box will open.
-
Select the 400watt.ies file in the folder.
-
Press the button. A dialog box will ask, "Load information from IES file?"
-
Press the button. The information from the IES file will be loaded in the fixture schedule.
noteOnce the information is loaded, you can manually modify the values as needed.
-
Set Arm Length to 3.
-
Set Volts ▾ to 277V 1P 2W.
-
Set Mounting ▾ to Pole.
-
Press the button to save your changes.
Create Light Fixture Type S2​
-
Press the button. The Copy dialog box will open.
-
Set New Light Fixture Callout to S2.
-
Press the button to create the light fixture type.
-
Press the button. The Select Light Fixture Block dialog box will open.
-
Set Light Fixture Description ☰ to Dual Pole Mounted, 180 Offset. It will be near the bottom of the list.
-
Press the button to set the block.
-
Set Number of Heads ▾ to Two, 180 degree offset.
-
Press the button to save your changes.